Part 4 Commands

z IN (Read I/O, flag as binary)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional

Optional

IN

I/O, flag

I/O, flag

CC

[Function]

Read the I/O ports or flags from the one specified in operand 1 through the other specified in
operand 2, to variable 99 as a binary.

2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

Binary

15 14 13 12 11 10 9 8

Input port number

ON OFF OFF OFF

OFF

ON

OFF

ON

1 0 0 0 0 1 0 1

Binary

2

7

+ 0 + 0 + 0 + 0 + 2

2

+ 0 + 2

0

128

+ 0 + 0 + 0 + 0 + 4 + 0 + 1

= 133

133

Variable 99

(Note 1)

A maximum of 32 bits can be input.

(Note 2)

When 32 bits have been input and the most significant bit is ON, the value read to variable
99 will be treated as a negative value.

(Note 3)

The read data format can be changed using a FMIO command (refer to the section on FMIO
command). (This function is available only in main application version 0.56 or later.)

[Example 1]

IN

8

15

Read input ports 8 through 15, to variable 99 as a
binary.

[Example 2]

LET

1

8

Assign 8 to variable 1.

LET

2

15

Assign 15 to variable 2.

IN

*1

*2

Read the input ports from the content of variable 1
(input port 8) through the content of variable 2 (input
port 15), to variable 99 as a binary.