82 part 4 commands – IAI America XSEL-KE User Manual

Page 97

Advertising
background image

82

Part 4 Commands

Operation type in the output field
CC: Command was executed successfully, ZR: Operation result is zero,
PE: Operation is complete, CP: Command part has passed, TU: Time up
EQ: Operand 1 = Operand 2, NE: Operand 1

z Operand 2,

GT: Operand 1 > Operand 2, GE: Operand 1

t Operand 2,

LT: Operand 1 < Operand 2, LE: Operand 1

d Operand 2

Command

Page

Condition

Operand 1

Operand 2

Output

Function

E
EDDO 182

Prohibited

Prohibited

Prohibited

CP

Declare end of DO

EDIF 180

Prohibited

Prohibited

Prohibited

CP

Declare end of IF

EDPA 208

Prohibited

Prohibited

Prohibited

CP

Declare end of palletizing setting

EDSL 186

Prohibited

Prohibited

Prohibited

CP

Declare end of SLCT

EDSR 114

Prohibited

Prohibited

Prohibited

CP

End subroutine

ELSE 180

Prohibited

Prohibited

Prohibited

CP

Declare execution destination when
IF command condition is not satisfied

EOR 96

Optional

Exclusive-OR operand
variable

Operand

ZR

Logical exclusive-OR

EXIT 115

Optional

Prohibited Prohibited

CP

End program

EXPG 116

Optional

Execution program number

(Execution program
number)

CC

Start program

EXSR 113

Optional

Execution subroutine
number

Prohibited

CP

Execute subroutine

F

FMIO 109

Optional

Format type

Prohibited

CP

Set IN (B)/OUT (B) command format

G
GACC 133

Optional

Variable number

Position number

CP

Get acceleration data

GDCL 134

Optional

Variable number

Position number

CP

Get deceleration data

GOTO 112

Optional

Jump destination tag
number

Prohibited

CP

Jump

GRP 143

Optional

Valid axis pattern

Prohibited

CP

Set group axis

GTTM 100

Optional

Time assignment variable

Prohibited

CP

Get time

GVEL 132

Optional

Variable number

Position number

CP

Get speed data

H
HOLD 144

Optional

(Input port to pause)

(HOLD type)

CP

Declare port to pause

HOME 156

Optional

Home-return axis pattern

Prohibited PE

Return to home

I
IFXX 178

Optional

Comparison variable

Comparison value

CP

Compare [EQ, NE, GT, GE, LT, LE]

INB 106

Optional

Head I/O, flag

Conversion digits

CC

Input BCD (8 digits max.)

IN 105

Optional

Head I/O, flag

End I/O, flag

CC

Input binary (32 bits max.)

ISXX 179

Optional

Column number

Column number, character
literal

CP

Compare strings

ITER 182

Optional

Prohibited

Prohibited CP

Repeat DO

JXWX 162

Optional

Axis operation pattern

Start I/O, flag

PE

Jog [FN, FF, BN, BF]

L
LEAV 181

Optional

Prohibited Prohibited CP

Pull out from DO

LET 86

Optional

Assignment variable

Assigned value

ZR

Assign

M

MOD 90

Optional

Remainder assignment
variable

Divisor ZR

Calculate remainder

MOVL 158

Optional

Destination position number

Prohibited PE

Move to specified position via
interpolation

MOVP 157

Optional

Destination position number

Prohibited

PE

Move to specified position

MULT 89

Optional

Multiplicand

Multiplier ZR

Multiply

MVLI 160

Optional

Travel position number

Prohibited PE

Move to relative position via
interpolation

MVPI 159

Optional

Travel position number

Prohibited

PE

Move to relative position

Advertising
This manual is related to the following products: