4 communication with the higher-order controller, 1 i/o function check – Festo Электромотор MTR-DCI User Manual

Page 100

Advertising
background image

5. Commissioning

5-22

Festo P.BE-MTR-DCI-IO-EN en 1209d

5.4

Communication with the higher-order controller

5.4.1

I/O function check

Warning
Danger of injury. Faults in parametrizing can cause injury
to people and damage to property.

Enable the controller only if the drive system is correctly
installed and parametrized.

In order that the MTR-DCI can be controlled via the control
interface, the manual device control via the control panel /
FCT software must be deactivated:

automatically when the operating voltage is switched on
(HMI = off)

via the control panel of the MTR-DCI with the menu com-
mand [HMI control] (HMI = off)

with FCT under “Device control” in the window “General
output”, (FCT = off).

In order to check the configuration and the axis set-up, enter
a simple test program or simulate control by directly setting
the inputs.

Please refer here to the function description of the control
interface in chapter 5.4.2.

Provide the necessary system inputs on the MTR-DCI.
There must be a 1-signal at the ENABLE input (controller
and power end stage enabled).

Take into account also the output signals. There will be a
1-signal at the READY output (readiness to operate) if the
controller and the power end stage are enabled and if no
fault has been recognized.

Program or start homing run as well as some positioning
movements.

Check the positioning reaction.

Advertising