A. technical appendix a-16, Physical variable conversion into increments, Tab. a/7: general formulae for conversion – Festo Электромотор MTR-DCI User Manual

Page 136

Advertising
background image

A. Technical appendix

A-16

Festo P.BE-MTR-DCI-IO-EN en 1209d

Physical variable

Conversion into increments

Item

POS [inc]

– Target position

– Reference point
– Project zero point
– Software end position,

positive

– Software end position,

negative

[µm]

}

[inc]

= POS

μm

x CF

μm

[µm] x [inc/µm]

[µinch]

}

[inc]

= POS

μinch

x (0.0254 x CF

μm

) *

= POS

μinch

x CF

μinch

[µinch] x [µm/µinch] x [inc/µm]

[µinch] x [inc/µinch]

[rot]

}

[inc]

= POS

Red

x CF

Red

[rot] x [inc/rot)

Speed

V [inc/s] =

– Positioning speed to tar-

get position

– Search speed during refer-

ence travel

– Positioning speed to the

axis zero point during ref-
erence travel

[µm]

}

[inc]

= V

μm

x CF

μm

[µm/s] x [inc/µm]

[µinch]

}

[inc]

= V

μinch

x (0.0254* x CF

μm)

*

= V

μinch

x CF

μinch

[µinch/s] x [µm/µinch] x [inc/µm]

[µinch/s] x [inc/µinch]

[rot]

}

[inc]

= V

Red

x CF

Red

[rot/s] x [inc/rot]

Acceleration

a [inc/s

2

] =

– Nominal acceleration

[µm]

}

[inc]

= a

μm

x CF

μm

[µm/s

2

] x [inc/µm]

[µinch]

}

[inc]

= a

μinch

x (0.0254* x CF

μm)

*

= a

μinch

x CF

μinch

[µm/s

2

] x [µm/µinch] x [inc/µm]

[µinch/s

2

] x [inc/µinch]

[rot]

}

[inc]

= a

Red

x CF

Red

[rot/s

2

] x [inc/rot]

* Conversion [µm]

}

[µinch] : 1

µ

Inch = 0.0254

µ

m

Tab. A/7:

General formulae for conversion

Advertising