Note
In order to restore the default settings you can, if required,
delete the EEPROM via the serial interface with the CI com-
mand 20F1h (Data memory control) (see chapter B.1.).
User-specific settings will then be lost.
•
Use CI commands only if you already have experience of
Service Data Objects.
•
If necessary, consult Festo.
B.1.1
Procedure for data transfer
Caution
In special application cases, access with CI commands
enables parametrizing and commissioning of the MTR-DCI
directly via the RS232 interface. It is, however, not suitable
for real-time capable communication.
Control via the RS232 does not correspond to the
designated use and requires e.g.:
– an estimation of the risk by the user
– ambient conditions free of interference
– saving the data transmission e.g. via the control
program of the host.
•
Use preferably the control panel or the FCT for commis-
sioning and parametrizing.
•
Use the control interface of the MTR-DCI for control
purposes.