B. Supplementary information

B-4

Festo P.BE-MTR-DCI-IO-EN en 1209d

Note
In order to restore the default settings you can, if required,
delete the EEPROM via the serial interface with the CI com-
mand 20F1h (Data memory control) (see chapter B.1.).
User-specific settings will then be lost.

Use CI commands only if you already have experience of
Service Data Objects.

If necessary, consult Festo.

B.1.1

Procedure for data transfer

Caution
In special application cases, access with CI commands
enables parametrizing and commissioning of the MTR-DCI
directly via the RS232 interface. It is, however, not suitable
for real-time capable communication.

Control via the RS232 does not correspond to the
designated use and requires e.g.:

– an estimation of the risk by the user

– ambient conditions free of interference

– saving the data transmission e.g. via the control

program of the host.

Use preferably the control panel or the FCT for commis-
sioning and parametrizing.

Use the control interface of the MTR-DCI for control
purposes.