Device control, Instructions on parametrizing and commissioning – Festo Электромотор MTR-DCI User Manual

Page 84

Advertising
background image

Diagnostic

positioning

Settings

}

HMI control
LCD adjustment

5. Commissioning

5-6

Festo P.BE-MTR-DCI-IO-EN en 1209d

5.2

Commissioning with the control panel (only MTR-DCI-...-H2)

Information on the button functions and on the menu com-
position of the control panel can be found in chapter 4.

Device control

In order that the control panel can control the connected
MTR-DCI, the control interface of the MTR-DCI must be
deactivated and controller enable must be set [HMI = on].
The actual status of the ENABLE input then has no effect.

Instructions on parametrizing and commissioning

Information on the current parametrizing of the motor unit
can be found in the menu [Diagnostic] on the control panel.

Carry out the following steps in order to commission the
MTR-DCI the first time with the control panel: Note the
detailed description in the chapters specified.

Commissioning (overview)

Chapter

1. Select the axis type and, if necessary, adapt the

parametrizing to suit your axis.

5.2.1

2. Set the following parameters for reference travel:

– Homing method
– Search speed to reference point
– Positioning speed to axis zero point

5.2.2

3. Carry out homing run.

5.2.2

4. Teach the following axis parameters for defining the

axis zero point and the working area:
– Offset of the axis zero point to the reference point
– Positive and negative software end positions.

5.2.3

Advertising