3. Installation

3-10

Festo P.BE-MTR-DCI-IO-EN en 1209d

3.4

Serial interface

Serial interface for parametrizing, commissioning and
diagnosing

Note
To connect a PC to the MTR-DCI, use the following cable
from Festo's accessories:

– Programming cable KDI-MC-M8-SUB-9

– Cable length 2.5 m (maximum permitted signal cable

length).

If necessary, remove the protective cap from the serial
interface of the MTR-DCI.

Connect the following terminals with the programming
cable:

the connection socket on the MTR-DCI

a serial interface COMx of the diagnostic PC.

M8x1 socket

Description

1

2

4

3

1

GND

Ground

2

TXD

RS232 transmitting cable

1)

3

RXD

RS232 receiving cable

1)

4

---

Reserved for service personal.
Do not connect.

1)

The levels correspond to the RS232 standard and enable a data
transmission rate of 9600 bit/s

Tab. 3/6:

Connecting the serial interface on the MTR-DCI