4 serial interface – Festo Электромотор MTR-DCI User Manual
Page 52

3. Installation
3-10
Festo P.BE-MTR-DCI-IO-EN en 1209d
3.4
Serial interface
Serial interface for parametrizing, commissioning and
diagnosing
Note
To connect a PC to the MTR-DCI, use the following cable
from Festo's accessories:
– Programming cable KDI-MC-M8-SUB-9
– Cable length 2.5 m (maximum permitted signal cable
length).
•
If necessary, remove the protective cap from the serial
interface of the MTR-DCI.
•
Connect the following terminals with the programming
cable:
–
the connection socket on the MTR-DCI
–
a serial interface COMx of the diagnostic PC.
M8x1 socket
Description
1
2
4
3
1
GND
Ground
2
TXD
RS232 transmitting cable
1)
3
RXD
RS232 receiving cable
1)
4
---
Reserved for service personal.
Do not connect.
1)
The levels correspond to the RS232 standard and enable a data
transmission rate of 9600 bit/s
Tab. 3/6:
Connecting the serial interface on the MTR-DCI