B.1.2 ci commands – Festo Электромотор MTR-DCI User Manual

Page 144

Advertising
background image

B. Supplementary information

B-8

Festo P.BE-MTR-DCI-IO-EN en 1209d

Note
Transmission of the command is repeated 8 times by the
host. After that the serial connection is regarded as unus-
able and is interrupted. Transmission must then be initial-
ized again.

B.1.2

CI commands

Caution
Loss of data

The Command Interpreter (CI) contains commands which
reorganise or delete parts of the memory. Existing data are
therefore destroyed:

•

Use preferably the FCT or the control panel for commis-
sioning and parametrizing.

•

Use the CI commands only in special applications which
require direct access to the controller.

•

Use CI commands only if you already know their effects
and if they are permitted for your MTR-DCI.

Access procedure

The higher-order controller sends the controller either a write
command (WRITE) to modify a parameter in the object direc-
tory, or a read command (READ) to read out a parameter.

For each command the higher-order controller receives a
response which either contains the value read or, in the case
of a write command, serves as an acknowledgement. The
transmitted value (1, 2 or 4 data bytes) depends on the data
type of the object to be read or written.

WRITE (W)

Write commands (W) transfer a value in the specified format
to the MTR-DCI. As a reply, write commands will be reflected
exactly character by character from the controller of the
MTR-DCI. A checksum <PS> will be inserted in front of the <CR>.