B. Supplementary information

B-20

Festo P.BE-MTR-DCI-IO-EN en 1209d

Record_Table_Element

CI access

20E0h

01h...03h

Struct

uint16, int32

rw

Description

Editing the entries in the position table:
1. Selecting the line (= position number) with Object 2032
2. Selection of the column under subindex 20E0: 01...03

20E0/01 20E0/02

V

20E0/03

Record
number

Pos. set
mode

Target
position

Profile
velocity

02

2032h

}

03

<1>

<...>

...

The values are only saved in the position table with this command; no move-
ment is made.
With Object 20E0, access is made partly to the same parameter as with the
corresponding Objects 607A, 6081.
Different data types are converted accordingly when they are read and written.

Positioning Mode 20E0h

01h

uint16

rw

Positioning mode
Values:
0 (0x0000):

absolute positioning (default)

1 (0x0001):

relative positioning

Target Position 20E0h

02h

int32

rw

Target position in increments (compare target position, Object 607A).
Value range: -2

31

...+(2

31

-1) (0x80000000...0x7FFFFFFF)

Default: 0