A.1 technical specifications – Festo Электромотор MTR-DCI User Manual

Page 123

Advertising
background image

A. Technical appendix

A-3

Festo P.BE-MTR-DCI-IO-EN en 1209d

A.1

Technical specifications

General

Protection class as per EN 60529

IP54 (Plug connector inserted or fitted with protec-
tive cap)

Relative humidity

0 to 95 %, non-condensing

Temperature range
– Operation
– Storage/transport

0 ... +50 °C
-25 ... +60 °C

Vibration

As per DIN/IEC 68/EN 60068 part 2-6:
Severity level 2:
0.35 mm path at 10 ... 60 Hz;
5 g acceleration at 60 ... 150 Hz

Shock

As per DIN/IEC 68/EN 60068 part 2-27
Severity level 2:
±30 g at 11 ms duration;
5 shocks in each direction

Protection against electric shock

1)

(protection against direct and indirect contact
as per IEC/DIN EN 60204-1)

By connection to a PELV power unit
(Protected Extra-Low Voltage)

Electromagnetic compatibility (EMC)

2)

See conformity declaration (www.festo.com)

Gear type

Planetary gear

Encoder (with 4-fold evaluation)

500 x4 —> 2000 inc/revolution
MTR-DCI-32: 300 x4 —> 1200 inc/revolution

Temperature monitoring

Switching off at temperature > 70 °C

Display resolution

128 x 64 pixels

Serial interface

RS232, 9600 baud

1)

The device is intended for industrial use.

2)

The maximum permitted I/O signal cable length is 30 m.

Advertising