Festo Электромотор MTR-DCI User Manual

Page 169

Advertising
background image

B. Supplementary information

B-33

Festo P.BE-MTR-DCI-IO-EN en 1209d

Homing_Method

CI access

6098h

00h

Var

uint8

rw

Description

Defines the method with which the drive carries out homing run.
The MTR-DCI supports the following modes:
Values

Function

-17 (0xEF)

Search for stop in negative direction

-18 (0xEE)

Search for stop in positive direction

23 (0x17)

Search for reference switch in positive direction

27 (0x1B)

Search for reference switch in negative direction (default)

Homing_Velocities

CI access

6099h

01h...02h

Array

uint32

rw

Description

Speeds during homing run in inc/s.

The following applies for firmware V1.19: The value must be divisible by 200,
otherwise it will be rounded to the next permitted value.

Search REF 6099h

01h

int32

rw

Speed when searching for the reference point REF

MTR-DCI-...

Value range (depends on gear)

...-32...-G7 (G14)

200...33000 DMES-18:

Z 0...6.1(3) mm/s

...-42...-G7 (G14)

200...50000 DMES-25:

Z 0...9.3(4.6) mm/s

...-52...-G7 (G14)

200...50000 DMES-40:

Z 0...14.8(7.3) mm/s

...-62...-G7 (G14) (G22)

200...56600 DMES-63:

Z 0...25.2(12.4)(7.7) mm/s

Default:
...-32...

27000 (0x006978) DMES-18:

Z 5(2.5) mm/s

...-42...

22400 (0x005780) DMES-25:

Z 4.2(2) mm/s

...-52...

16800 (0x0041A0) DMES-40:

Z 5(2.5) mm/s

...-62...

16800 (0x005780) DMES-63:

Z 7.5(3.7)(2.3) mm/s

Search AZ 6099h

02h

int32

rw

Speed of travel to the axis zero point AZ
Value range: see Object 6099/01h

Advertising