6. Operating, maintenance and diagnosis

6-11

Festo P.BE-MTR-DCI-IO-EN en 1209d

Fault

Possible cause

POSITION ERROR

Position fault (drag fault)
Possible causes:
– The drive is blocked
– The positioning speed is too high
– The work load is too heavy

Check ...
– the mechanical parts of the drive
– the speed of the positioning set.

POWER DOWN

Voltage monitoring
Possible causes:
– Voltage supply too low

MTR-DCI 32/42/52: U < 18 V
MTR-DCI 62: U < 34 V

– Voltage dips under load

Check the voltage supply.
– Power unit too weak?
– Supply line too long?

TARGET POSITION OUT
OF LIMIT

The specified nominal position is outside the permitted positioning range.

Check the ...
– software end positions
– the set/nominal position
– the reference of the nominal position (absolute or relative).