6. Operating, maintenance and diagnosis

6-9

Festo P.BE-MTR-DCI-IO-EN en 1209d

6.2.3

Fault messages on the display (only type MTR-DCI-...-H2)

Messages

Messages inform about operating states.

Message

Cause

Attention!
Motor moves...

Message at the start of a Teach procedure. After
confirmation with the <ENTER> button the drive
moves in the Teach mode.

Profile velocity
= 0.
Please teach v.

The menu command [Move posit set] is not
processed because the positioning speed of the
positioning set v = 0. Modify the parametrizing or
select a different positioning set.

Temperature
OK

Operating temperature lies in permitted range
again after exceeding/not reaching limit.

Warning

In the event of non-permitted operating temperatures, the
motor unit displays an appropriate warning. If a positioning
task is running, it will not be interrupted.

Warning

Cause

HOT
TEMPERATURE

Operating temperature 70 °C < T < 80 °C,
Check whether drive is overloaded, check the
mechanical parts, e.g. for stiffness, reduce
ambient temperature.

COLD
TEMPERATURE

Operating temperature < -10 °C,
if necessary, increase ambient temperature.

Fault

If there is a fault, the drive will be stopped. The fault LED will
flash.

Eliminate the cause of the fault.

Acknowledge the fault message.

on the control panel with <Enter>,

via I/O with a falling edge at the ENABLE signal,

with the “Quit fault” button in the Festo Configuration
Tool.

Advertising