5. Commissioning
5-8
Festo P.BE-MTR-DCI-IO-EN en 1209d
Axis type
Feed constant
[mm/revolution]
Measuring
system
Festo positioning
axis
1) 2)
DMES-18
1.5
Metric
3)
DMES-25
2.5
DMES-40
4
DMES-63
6
Rotation axis
—
Degree or
revolutions
Linear axis
2)
According to the type
plate or technical
specifications of the
axis
Metric
3)
1)
Values defined at factory
Z spindle pitch of the axis [mm]
2)
If an external gear is used, the gear factor can be set with
FCT.
3)
Pre-setting metric; inches can only be set with FCT
Tab. 5/2:
Parametrizing the axis