Festo Электромотор MTR-DCI User Manual

Page 33

Advertising
background image

1. System summary

1-15

Festo P.BE-MTR-DCI-IO-EN en 1209d

Search for fixed stop

With this reference travel method, at first the drive moves at
search speed in a negative or positive direction until it
reaches the fixed stop. A rise in the motor current signals that
the stop has been reached. When the maximum motor cur-
rent is reached at the same time as the motor is at a stand-
still, the MTR-DCI recognizes that the stop, and therefore the
reference position, has been reached.

As the axis should not stand still at the stop, the axis zero
point offset must be ≠ 0 (min. 0.25 mm).

+

REF (-)

AZ

REF (+)

1

2

AZ

1

Stop in a negative direction

2

Stop in a positive direction

Fig. 1/4:

“Search for fixed stop” reference travel method