B. Supplementary information

B-35

Festo P.BE-MTR-DCI-IO-EN en 1209d

Position_Control_Parameter_Set

Save Position 60FBh

20h

uint16

r

240 (0x00F0) = current position will

not be saved at power-off.

Homing run must be carried out each time the device is switched on.
This value is fixed and cannot be overwritten.
The following applies up to firmware version V1.35: If this parameter does not
contain the value 240 (0x00F0), overwrite this with value 240 (0x00F0).

Local_Digital_Inputs

CI access

60FDh

00h

uint32

r

Description

Mapping the digital inputs
With MTR-DCI-...IO:
Bit 0...15:

Reserved (= 0)

Bit 16...19:

Current record number (compare control byte 3)

Bit 20:

START

Bit 21:

ENABLE

Bit 22...31:

Reserved (= 0)

Local_Digital_Outputs

CI access

60FEh

01h...02h

uint32

r

Description

Mapping the digital outputs

Digital Outputs 60FEh

01h

uint32

r

With MTR-DCI-...IO:
Bit 0...15:

Reserved (= 0)

Bit 16:

READY

Bit 17:

MC

Bit 18...31:

Reserved (= 0)

Mask 60FEh

02h

uint32

r

With the MTR-DCI-...IO always 0 (writing not permitted).