Festo Электромотор MTR-DCI User Manual

Page 170

Advertising
background image

B. Supplementary information

B-34

Festo P.BE-MTR-DCI-IO-EN en 1209d

Position_Control_Parameter_Set

CI access

60FBh

12h...15h,
17h, 20h

Array

uint16

rw

Description

Control parameters as well as parameters for “quasi-absolute position
registering”
Write only in service cases.

Gain Position 60FBh

12h

uint16

rw

Gain position controller
Value range: 1...200
Default:
MTR-DCI-32: 60

MTR-DCI-42/52/62: 35

Gain Velocity

(speed gain)

60FBh

13h

uint16

rw

Gain speed controller
Value range: 100...500
Default:
MTR-DCI-32: 500

MTR-DCI-42/52: 230

MTR-DCI-62: 200

I-Fraction Velocity

(I-share of speed)

60FBh

14h

uint16

rw

I-share speed controller
Value range: 100...500
Default:
MTR-DCI-32: 500

MTR-DCI-42/52: 320

MTR-DCI-62: 150

Gain Current 60FBh

15h

uint16

rw

Gain current controller
Value range:
MTR-DCI-32: 200...1000

MTR-DCI-42/52: 200...800

Default:
MTR-DCI-32: 1000

MTR-DCI-42/52: 400

MTR-DCI-62: 300

Gain Velocity

Trajectory

60FBh

17h

uint16

rw

Gain speed controller – trajectory generator
Values: 1, 2
Default:
MTR-DCI-32: 1

MTR-DCI-42/52/62: 2

Advertising