B. Supplementary information

B-18

Festo P.BE-MTR-DCI-IO-EN en 1209d

Group 2xxx

Record_Number

CI access

2032h

01h

Array

1)

uint8

rw

Description

Select a position record via the record number.

The record number is saved as the target for write and read operations on the
following Objects:
– Intended for access via the CI interface:

– Object 20E0/01h...03h: record_table_element
or
– Object 607Ah: target_position
– Object 6081h: profile_velocity

Record Number 2032h

01h

uint8

rw

Record number: Read or write
Values:
00 (0x00): Reserved,

do not use (CANopen)

01 (0x01): Reserved,

do not use (CANopen)

02 (0x02): Position record 0 (default)
03 (0x03): Position record 1
04 (0x04): Position record 2
...

Position record ...

18 (0x12): Position record 16 (homing run)

1)

Pseudo-array due to compatibility