4. Control panel (MTR-DCI-...-H2IO)
4-10
Festo P.BE-MTR-DCI-IO-EN en 1209d
[System param]
Menu command for displaying the following system para-
meters and data:
[System param]
Description
V power
[V]
Supply voltage
V dd
[V]
Voltage of display
I max
[A]
Maximum current
I act
[A]
Current current
Temp
[°C]
Operating temperature
Cycle
Number of positioning movements
In signal
Hexadecimal representation of the inputs
Bit 0: I0
Bit 1: I1
Bit 2: I2
Bit 3: I3
Bit 4: START
Bit 5: ENABLE
Out signal
Hexadecimal representation of the outputs
Bit 0: READY
Bit 1: MOTION COMPLETE
Ref. switch
on/off
Signal at reference switch input
Mode
e.g. mm
Measuring system
Hom.meth.
– bl.pos
– bl.neg
– sw.pos
– sw.neg
Fixed stop in positive direction
Fixed stop in negative direction
Reference switch in positive direction
Reference switch in negative direction
Gear
e.g. 6.75
Gear ratio of the MTR-DCI