3.5

Input for external reference switch

If you are not using a reference switch:

Seal the connection with the protective cap supplied
(ISK-M8).

Connecting the reference switch:

Use the correct switch type “normally-open contact” in
the PNP variant for the reference switch.

When connecting the reference switch use a sensor with a
screw-type lock (external thread M8x1) at the end of the
cable or use the connecting cable KM8-M8 with a screw-
type lock as an adapter.

Use e.g. the following proximity switches from Festo:

magnetic proximity switch SMT-8F

inductive proximity switch SIEN-...-M8B

When selecting the sensor, note that the accuracy of the
switchover point of the sensor determines the accuracy of
the reference point.

M8x1 socket

Description

1

3

4

1

DC +24 V

DC +24 V voltage output
(only for reference switch)

4

REF

Contact reference switch

3

GND

Ground

Tab. 3/7:

Connection “Ref ” (reference switch) on the
MTR-DCI

The power supply for the reference switch (DC 24 V / Ground)
is provided via pin 1/3.