Festo Электромотор MTR-DCI User Manual
Page 40

2. Mounting
2-6
Festo P.BE-MTR-DCI-IO-EN en 1209d
L3
L3 x 0.5
F
y
F
x
Fig. 2/1:
Forces and torques
Forces and torques
32
42
52
62
MTR-DCI-...-G7 1-stage
– Radial shaft load
– Axial shaft load
– Maximum permitted shaft output torque of
the gear
1)
F
y
[N]
F
x
[N]
Mx [Nm]
40
10
0.4
160
50
0.8
200
60
2.0
240
50
4
MTR-DCI-...-G14 /G22 2-stage
– Radial shaft load
– Axial shaft load
– Maximum permitted shaft output torque of
the gear
1)
F
y
[N]
F
x
[N]
M
x
[Nm]
70
20
1.0
230
80
7.5
320
100
12.0
360
70
25
2)
1)
With operating factor cb = 1.0 (3 hours operation daily, no shocks, direction of rotation constant).
The gear output torque or the motor unit is usually much lower, see Technical specifications,
appendix A, Mechanical specifications.
2)
MTR-DCI-62...-G22: In the start-up phase speed torque peaks up to 37 Nm are possible at 20 A
peak current.
Tab. 2/2:
Permitted loading of the gear shaft