1. System summary

1-9

Festo P.BE-MTR-DCI-IO-EN en 1209d

1.4

Operational reliability

An extensive system of sensors and monitoring functions
ensure operational safety:

i

2

t-monitoring

Temperature monitoring (measuring the motor tempera-
ture and the power end stage temperature)

Current monitoring

Voltage monitoring

Recognizing faults in the internal voltage supply.

MTR-DCI-62...: detection of overvoltages in the inter-
mediate circuit; brake chopper integrated.

Drag fault monitoring

Software end position recognition.

Observe the following:

By the arrangement of the limit switches and, if neces-
sary, additionally by means of mechanical stops, make
sure that the axis always lies within the permitted posi-
tioning range.