background image

3. Installation

3-5

Festo P.BE-MTR-DCI-IO-EN en 1209d

If non-assigned plug connectors are touched, there is a
danger that damage may occur to the MTR-DCI or to other
parts of the system as a result of ESD (electrostatic dis-
charge). Place protective caps on unused connections in
order to prevent such discharges.

The plug connectors of the following Festo cables have been
designed so that, when inserted and screwed tight, or if fitted
with protective covers, the connections on the MTR-DCI will
comply with protection class IP54.

Connection

Cable

Designation

Length [m]

Voltage supply

Power supply cable

KPWR-MC-1-SUB-9HC

2.5 / 5 / 10

I/O control

Pilot line

KES-MC-1-SUB-9HC

2.5 / 5 / 10

Serial interface

Programming cable

KDI-MC-M8-SUB-9

2.5

Homing Switch

If necessary, connecting
cable with screw-type lock

KM8-M8-GSGD

0.5 / 1 / 2 / 5

Tab. 3/2: Overview of cables (accessories)

In order to guarantee compliance with the IP protection class:

Seal unused M8 connections with ISK-M8 protective caps
(accessories).

Hand-tighten the union nuts/locking screws of the plugs.
Observe the permissible tightening torques specified in
the documentation for the lines and plugs used.

Note

Lay all moveable motor and sensor cables free of bends
and free of mechanical stress, if necessary, in a drag
chain.

Observe the maximum specified cable lengths.