B. Supplementary information

B-24

Festo P.BE-MTR-DCI-IO-EN en 1209d

HMI_Parameter (MMI parameter)

CI access

20FFh

01h, 02h

Array

uint8

rw

Description

Parametrizing the MMI functions (only with MTR-DCI-...-H2...)

LCD Current 20FFh

01h

uint8

rw

Value range: 1...5 (0x01...0x05). Default: 5 (0x05)

LCD Contrast 20FFh

02h

uint8

rw

Value range: 0...63 (0x00...0x3F). Default: 0 (0x00)

Communication_Error

CI access

2FF0h

00h

Var

uint16

r

Description

Special object, see section B.1.1.
In the case of a transmission fault, the value <0xFF> will be transferred instead
of the regular reply.

Device_Fault

CI access

2FF1h

00h

Var

uint16

rw

Description

Read out or delete the active device fault.
Explanations of the fault messages can be found in chapter 6.2.3.

Write:

Delete all device faults = <0> 0x0000

Read:

Bit 0

POSITION ERROR

Bit 1

EMERGENCY STOP

Bit 2

HOMING ERROR

Bit 3

OVERHEATING

Bit 4

POWER DOWN

Bit 5

i

2

t-ERROR

Bit 6

HARDWARE ERROR

Bit 7

TARGET POSITION OUT OF LIMIT

Bit 8

LAST POSITION NOT SAVED

Bit 9...15 Reserved = <0> 0x0000

Cycle_Number

CI access

2FFFh

00h

Var

uint32

r

Description

Number of positioning records carried out, homing run etc.
Value range: 0...(2

32

-1)