Festo Электромотор MTR-DCI User Manual
Page 50

3. Installation
3-8
Festo P.BE-MTR-DCI-IO-EN en 1209d
The internal power and controller electronics are supplied
with DC voltage via the power supply connection. The power
supply must fulfil the following requirements:
Specifications
MTR-…-32
MTR-…-42
MTR-…-52
MTR-…-62
Rated voltage
DC 24 V ±10 %
DC 48 V +5...-1 %
Rated current
0.73 A ±20 %
2 A ±20 %
5 A ±20 %
6.19 A ±20 %
Peak current
2.1 A ±20 %
3.8 A ±20 %
7.7 A ±20 %
20 A ±20 %
Tab. 3/3:
Power supply
Recommendation
Use a closed-loop controlled power unit with high output
reserve and external fuse:
MTR-…-32
MTR-…-42
MTR-…-52
MTR-…-62
Power unit (closed-
loop controlled)
DC 24 V /3 A
DC 24 V / 6 A
DC 24 V / 10 A
DC 48 V / 20 A
External fuse
secondary side
5 A slow-blowing
7 A slow-blowing 10 A slow-blowing
25 A slow-blowing
Tab. 3/4:
Selecting the power unit
A1
A2
A1
A2
Fig. 3/2:
Connection example – power supply with external
fuse