Festo Электромотор MTR-DCI User Manual

Page 50

Advertising
background image

3. Installation

3-8

Festo P.BE-MTR-DCI-IO-EN en 1209d

The internal power and controller electronics are supplied
with DC voltage via the power supply connection. The power
supply must fulfil the following requirements:

Specifications

MTR-…-32

MTR-…-42

MTR-…-52

MTR-…-62

Rated voltage

DC 24 V ±10 %

DC 48 V +5...-1 %

Rated current

0.73 A ±20 %

2 A ±20 %

5 A ±20 %

6.19 A ±20 %

Peak current

2.1 A ±20 %

3.8 A ±20 %

7.7 A ±20 %

20 A ±20 %

Tab. 3/3:

Power supply

Recommendation
Use a closed-loop controlled power unit with high output
reserve and external fuse:

MTR-…-32

MTR-…-42

MTR-…-52

MTR-…-62

Power unit (closed-
loop controlled)

DC 24 V /3 A

DC 24 V / 6 A

DC 24 V / 10 A

DC 48 V / 20 A

External fuse
secondary side

5 A slow-blowing

7 A slow-blowing 10 A slow-blowing

25 A slow-blowing

Tab. 3/4:

Selecting the power unit

A1

A2

A1

A2

Fig. 3/2:

Connection example – power supply with external
fuse

Advertising