Permitted value ranges

Transferred parameters and values are checked by the
MTR-DCI before being accepted.

Non-permitted parameters will not be accepted.

Values outside the permitted value range will be limited
to the next valid value.

Note
In the case of non-permitted parameters or values, no fault
message will appear in the reply, the value transferred will
always be returned.

Recommendation:

Check that values and parameters have been written
correctly by downloading the current contents of the
parameter or value with one of the following Read
commands:

Transmission faults

If there are transmission faults between the Host (PC) and the
target device, e. g. due to faults in the Host command, Object
2FF0:FF<CR> will be transferred instead of the regular reply.

Possible causes:

incorrect starting character, separating character or
empty character

incorrect hex figure

incorrect value type.

Name

Class

IIII

SS

Type

Acc

communication_
error

Var

2FF0

00

UINT16

R

Value

Comment

0xFF

In the case of a transmission fault, the value <0xFF>
will be transferred instead of the regular reply.