Festo Электромотор MTR-DCI User Manual

Page 157

Advertising
background image

B. Supplementary information

B-21

Festo P.BE-MTR-DCI-IO-EN en 1209d

Record_Table_Element

Velocity

(speed)

20E0h

03h

int32

rw

Positioning speed in increments (compare profile velocity, Object 6081).
Value range
MTR-DCI-...

Value range

DMES-...

...-32...-G7

0...66000

Z 0...12 mm/s (DMES-18)

...-32...-G14

Z 0...6.0 mm/s (DMES-18)

...-42...-G7

0...100000

Z 0...18.5 mm/s (DMES-25)

...-42...-G14

Z 0...9.1 mm/s (DMES-25)

...-52...-G7

0...100000

Z 0...29.6 mm/s (DMES-40)

...-52...-G14

Z 0...14.6 mm/s (DMES-40)

...-62...-G7

0...113400

Z 0...50.4 mm/s (DMES-63)

...-62...-G14

Z 0...24.7 mm/s (DMES-63)

...-62...-G22

Z 0...15.3 mm/s (DMES-63)

Default: 0 (0x00000000)
Note: Negative values will be set to zero.
The following applies for firmware V1.19: All values should be divisible by 200,
otherwise they will be rounded.

Axis_Parameter

CI access

20E2h

01h...03h

Array

int32

rw

Description

Specifying and reading the axis parameters e.g. for diagnosis.

Axis Length 20E2h

01h

int32

rw

Axis length in increments (can be set as desired, for future extensions)
Value range: -2

31

...+(2

31

-1)

Default: 1

Gear Numerator

(gear counter)

20E2h

02h

int32

rw

Gear ratio – counter, reserved for future extensions
Fix: 1

Gear denominator

(gear denominator)

20E2h

03h

int32

rw*

Gear ratio - denominator, reserved for future extensions.
Fix: 1
* Write only Festo (factory or service)