B.1.4 object description – Festo Электромотор MTR-DCI User Manual

Page 152

Advertising
background image

B. Supplementary information

B-16

Festo P.BE-MTR-DCI-IO-EN en 1209d

B.1.4

Object description

Password

CI access

20FAh

01h...02h Array

V-string

rw/r

Description

Managing the FCT password, entering the super password

FCT Password

(FCT password)

20FAh

01h

V-string

rw

Password for the FCT software
Value:

<........> (Fix 8 characters (ASCII, 7-bit)

Default: <00000000> (delivery status and after resetting)

Super Password

(super password)

20FAh

02h

V-string

rw

Entering the super password
Resets all passwords (FCT password and HMI password, object 20FB).
Contact the Festo Service if you require the super password.

1

Name of the parameter in English
(German in brackets)

2

CI object number

3

Subindices of the parameter

4

Class of the element

5

Type of the element

6

Description of the parameter

7

If available: description of the subindices

8

Read/write permission:
r

= read only

w

= write only

rw

= read and write

Fig. B/1: Representing the object entries