Festo Электромотор MTR-DCI User Manual

Page 173

Advertising
background image

B. Supplementary information

B-37

Festo P.BE-MTR-DCI-IO-EN en 1209d

Drive_Data

CI access

6510h

31h, 32h,
40...43h, A0h

Array

Description

General motor data

Following error 6510h

22h

uint32

rw

Following error monitoring

Output Stage

Temp

(temp. end stage)

6510h

31h

uint16

r

Temperature of the end stage in °C.

-40...+85

Output Stage Max.

Temp.

(max. temp. end

stage)

6510h

32h

uint16

r

Maximum temperature of the end stage in °C. Fix: 80

Motor Rated

Current

6510h

40h

uint32

r

Rate motor current in mA, identical to Object 6075h.
Values:
MTR-DCI-32: 730
MTR-DCI-42: 2000
MTR-DCI-52: 5000
MTR-DCI-62: 6190

Current Limit

(max. motor

current)

6510h

41h

uint16

rw

Upper current limit value in 1/1000 of the rated motor current (identical to
Object 6073h)
Value range: 1...2000 (0x0001...0x07D0)
Default: 1500 (0x05DC) = rated motor current x 1.5

Lower Current Limit

(min. motor

current)

6510h

42h

int16

r

Lower current limit value in 1/1000 of the rated motor current
Value range: -2000...-1

Default: -1500 (0xFA24)

I/O Control 6510h

43h

uint16

rw

Activating/deactivating the I/O interface.
Value: 0: Control via HMI (control panel) or FCT

Note: For controller enable with FCT controller, set ENABLE

OPERATION (see Object 6040h).

1: Control via I/O (default)

Advertising