Setting 7: preset 7 – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 103

Advertising
background image

Time

UP

S1-SC

S6-SC

OFF

OFF

d1-03

d1-01 (Enabled when b1-01 = 0)

L4-01

b2-01

OFF

DC Injection braking

ON

ON

ON

P2-PC

Holding brake

Fast/Slow

Output frequency

0

Frequency Detection 2
(H2-03=05)

Closed

Closed

Open

b6-02

b6-01

Input

Output

Figure 4.9 Holding Brake Time Chart

u

Setting 7: Preset 7

Table 4.15 Preset 7: Parameters and Settings

No.

Parameter Name

Default Setting

A1-02

Control Method Selection

0: V/f Control

b1-01

Frequency Reference Selection 1

0: Operator

C1-01

Acceleration Time 1

3.0 s

C1-02

Deceleration Time 1

3.0 s

C6-01

Drive Duty Selection

0: Heavy Duty

C6-02

Carrier Frequency Selection

2: 5 kHz

d1-01

Frequency Reference 1

6.0 Hz

d1-02

Frequency Reference 2

30.0 Hz

d1-03

Frequency Reference 3

60.0 Hz

H1-05

Multi-Function Digital Input Terminal S5

Function

3: Multi-Step Speed 1

H1-06

Multi-Function Digital Input Terminal S6

Function

4: Multi-Step Speed 2

H2-02

Terminals P1 Function Selection

37: During frequency output

L3-04

Stall Prevention Selection during

Deceleration

0: Disabled

L8-05

Input Phase Loss Protection Selection

1: Enabled

<1>

4.5 Application Selection

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide

103

4

Start-Up Programming & Operation