Crimping. the wire gauges listed in, Table c.6, C.2 ul and csa standards – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 224

Advertising
background image

Table C.6 Wire Gauge and Torque Specifications

Drive

Model

Terminal

Recomm.

Gauge

AWG, kcmil

Wire Range
AWG, kcmil

Screw

Size

Tightening

Torque

N•m (lb.in.)

BA0001

BA0002

BA0003

R/L1, S/L2, T/L3

14

18 to 14

M3.5

0.8 to 1.0

(7.1 to 8.9)

U/T1, V/T2, W/T3

14

18 to 14

⊖, ⊕1, ⊕2

18 to 14

B1, B2

18 to 14

14

18 to 14

BA0006

R/L1, S/L2, T/L3

12

14 to 10

M4

1.2 to 1.5

(10.6 to 13.3)

U/T1, V/T2, W/T3

14

14 to 10

⊖, ⊕1, ⊕2

14 to 10

B1, B2

14 to 10

10

14 to 10

BA0010

R/L1, S/L2, T/L3

10

14 to 10

M4

1.2 to 1.5

(10.6 to 13.3)

U/T1, V/T2, W/T3

14

14 to 10

⊖, ⊕1, ⊕2

14 to 10

B1, B2

14 to 10

10

14 to 10

BA0012

R/L1, S/L2, T/L3

10

14 to 10

M4

2.3 to 2.5

(20.4 to 22.1)

U/T1, V/T2, W/T3

14

14 to 10

⊖, ⊕1, ⊕2

14 to 10

B1, B2

14 to 10

10

14 to 10

BA0018

R/L1, S/L2, T/L3

8

12 to 8

M5

2.3 to 2.5

(20.4 to 22.1)

U/T1, V/T2, W/T3

10

12 to 8

⊖, ⊕1, ⊕2

12 to 8

B1, B2

12 to 8

8

12 to 8

2 to 2.5

(17.7 to 22.1)

C.2 UL and CSA Standards

224

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide

Advertising