Step

Display/Result

1. Turn on the power to the drive. The initial display appears.

2. Set the frequency reference to F6.00 (6 Hz).

3. Press the

key to start the motor.

4. The motor should accelerate up to 6 Hz while the RUN light is on.

STOP

off

on

5. Press the

STOP

key to stop the motor. The RUN light will flash

until the motor comes to a complete stop.

flashing

off

n

Run the Drive using Digital Input Terminals: b1-02 = 1

This setting uses the digital input terminals to enter the run command. The factory setting is

a 2-Wire sequence.

Using a 2-Wire Sequence

Digital Input Terminals

ON

OFF

S1

Forward Run

Stop

S2

Reverse Run

Stop

S1

S2

SC

Drive

Forward Run

Reverse Run

Digital Input Common

Figure 4.12 Example Wiring Diagram for 2-Wire Sequence

4.6 Basic Drive Setup Adjustments

110