6 basic drive setup adjustments – Yaskawa J1000 Compact Vector Control Drive User Manual
Page 110

Step
Display/Result
1. Turn on the power to the drive. The initial display appears.
2. Set the frequency reference to F6.00 (6 Hz).
3. Press the
key to start the motor.
4. The motor should accelerate up to 6 Hz while the RUN light is on.
STOP
off
on
5. Press the
STOP
key to stop the motor. The RUN light will flash
until the motor comes to a complete stop.
flashing
off
n
Run the Drive using Digital Input Terminals: b1-02 = 1
This setting uses the digital input terminals to enter the run command. The factory setting is
a 2-Wire sequence.
Using a 2-Wire Sequence
Digital Input Terminals
ON
OFF
S1
Forward Run
Stop
S2
Reverse Run
Stop
S1
S2
SC
Drive
Forward Run
Reverse Run
Digital Input Common
Figure 4.12 Example Wiring Diagram for 2-Wire Sequence
4.6 Basic Drive Setup Adjustments
110
YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide