1 using the digital led operator – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 83

Advertising
background image

Table 4.1 Keys and Displays on the LED Operator

No.

Display

Name

Function

1

Data Display Area

Displays the frequency reference, parameter number, etc.

2

ESC Key

Returns to the previous menu.

3

RESET Key

Moves the cursor to the right.

Resets the drive to clear a fault situation.

4

RUN Key

Starts the drive.

5

Up Arrow Key

Scrolls up to select parameter numbers, setting values, etc.

6

Down Arrow Key

Scrolls down to select parameter numbers, setting values, etc.

7

STOP

STOP Key

Stops the drive.

Note: Stop priority circuit. Pressing the STOP key will always

cause the drive to stop the motor, even when a Run command is

active at an external Run command source. Set parameter o2-06

to 0 to disable the STOP key priority.

8

ENTER Key

Selects all modes, parameters, settings, etc.

Selects a menu item to move from one display screen to the next.

9

LO/RE Selection Key

Switches drive control between the operator (LOCAL) and the

control circuit terminals (REMOTE).

Note: LOCAL/REMOTE key effective during stop in drive

mode. If the digital operator could change from REMOTE to

LOCAL by incorrect operation, set o2-01 (LOCAL/REMOTE

Key Function Selection) to “0” (disabled) to disable LOCAL/

REMOTE key.

10

RUN Light

Lit while the drive is operating the motor.

11

LO/RE Light

Lit while the operator (LOCAL) is selected to run the drive.

12

ALM LED Light

Refer to LED Screen Displays on page 84

.

13

REV LED Light

14

DRV LED Light

15

FOUT LED Light

4.1 Using the Digital LED Operator