2 fault detection, Fault displays, causes, and possible solutions, Fault detection – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 131

Advertising
background image

5.2

Fault Detection

u

Fault Displays, Causes, and Possible Solutions

Table 5.2 Detailed Fault Displays, Causes, and Possible Solutions

Digital Operator Display

Fault Name

bUS

Option Communication Error
• After establishing initial communication, the connection was lost.
• Only detected when the run command frequency reference is assigned to an

option card.

Cause

Possible Solution

No signal received from the PLC. • Check for faulty wiring.

• Correct the wiring.
• Check for loose wiring and short circuits. Repair as needed.

The communication cable is faulty

or a short circuit exists.

A communications data error

occurred due to noise.

• Check the various options available to minimize the effects of noise.
• Counteract noise in control circuit, main circuit, and ground wiring.
• Ensure that other equipment such as switches or relays do not cause noise and

use surge suppressors if required.

• Use cables recommended by Yaskawa or another type of shielded line. Ground

the shield on the controller side or on the drive input power side.

• Separate all wiring for communications devices from drive input power lines.

Install an EMC noise filter to the input side of the drive input power.

The option card is damaged.

• Replace the option card if there are no problems with the wiring and the error

continues to occur.

The option card is not properly

connected to the drive.

• The connector pins on the option card are not properly lined up with the

connector pins on the drive.

• Reinstall the option card.

Digital Operator Display

Fault Name

CE

MEMOBUS/Modbus Communication Error
Control data was not received for the CE detection time set to H5-09.

Cause

Possible Solution

Faulty communications wiring, or a

short circuit exists.

• Check for faulty wiring.
• Correct the wiring.
• Check for loose wiring and short circuits. Repair as needed.

5.2 Fault Detection

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide

131

5

Troubleshooting

Advertising