2 fault detection – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 136

Advertising
background image

Digital Operator Display

Fault Name

Cause

Possible Solution

Hardware is damaged.

Replace the drive.

Digital Operator Display

Fault Name

CPF25

Terminal Board Not Connected

Cause

Possible Solution

Terminal board is not connected

correctly.

Reconnect the terminal board to the connector on the drive, then cycle the power

to the drive.

Digital Operator Display

Fault Name

dEv

Speed Deviation (for Simple V/f with PG)
According to the pulse input (RP), the speed deviation is greater than the setting

in F1-10 for longer than the time set to F1-11.

Cause

Possible Solution

Load is too heavy.

Reduce the load.

Acceleration and deceleration

times are set too short.

Increase the acceleration and deceleration times (C1-01 through C1-08).

The load is locked up.

Check the machine.

Parameters are not set

appropriately.

Check the settings of parameters F1-10 and F1-11.

Motor brake engaged.

Ensure the motor brake releases properly.

Digital Operator Display

Fault Name

dWFL

DriveWorksEZ Fault

dWAL

DriveWorksEZ Program Error Output

Cause

Possible Solution

Fault output by DriveWorksEZ

Correct the cause of the fault.

Digital Operator Display

Fault Name

E5

MECHATROLINK Watchdog Timer Error
The watchdog timed out.

Cause

Possible Solution

Data has not been received from the

PLC, triggering the watchdog

timer.

Execute DISCONNECT or ALM_CLR, then issue a CONNECT command or

SYNC_SET command and proceed to phase 3.

Digital Operator Display

Fault Name

EF0

Option Card External Fault
An external fault condition is present.

5.2 Fault Detection

136

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide

Advertising