5 auto‑tuning fault detection, Auto‑tuning codes, causes, and possible solutions, 5 auto-tuning fault detection – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 158: Auto-tuning codes, causes, and possible solutions, Auto-tuning fault detection

Advertising
background image

5.5

Auto-Tuning Fault Detection

Auto-Tuning faults are shown below. When the following faults are detected, the fault is

displayed on the digital operator and the motor coasts to a stop. No fault or alarm outputs will

occur

u

Auto-Tuning Codes, Causes, and Possible Solutions

Table 5.5 Detailed Auto-Tuning Codes, Causes, and Possible Solutions

Digital Operator Display

Error Name

End1

Excessive V/f Setting. Displayed after Auto-Tuning is complete.

Cause

Possible Solution

The torque reference exceeded

20% during Auto-Tuning.

• Before Auto-Tuning the drive, verify the information written on the motor

nameplate and enter that data to T1-03 through T1-05.

• Enter proper information to parameters T1-03 to T1-05 and repeat

Auto-Tuning.

• If possible, disconnect the motor from the load and perform Auto-Tuning.

The no-load current exceeded 80%

of the drive rated current during

Auto-Tuning.

Digital Operator Display

Fault Name

End2

Motor Iron-Core Saturation Coefficient. Detected only during Rotational

Auto-Tuning and displayed after Auto-Tuning is complete.

Cause

Possible Solution

Motor data entered during

Auto-Tuning was incorrect.

• Enter the correct data.
• Restart Auto-Tuning and enter the correct information.

Auto-Tuning calculated values

outside the parameter setting range,

assigning the iron-core saturation

coefficient (E2-07, E2-08) a

temporary value.

• Check and correct faulty motor wiring.
• Disconnect the motor from machine and perform Rotational Auto-Tuning.

Digital Operator Display

Fault Name

End3

Rated Current Setting Alarm (displayed after Auto-Tuning is complete)

Cause

Possible Solution

• The motor line-to-line

resistance and the motor-rated

current are not consistent with

one another.

• The correct current rating

printed on the nameplate was

not entered into T1-04.

• Check T1-04 setting.
• Check the motor data and repeat Auto-Tuning.

5.5 Auto-Tuning Fault Detection

158

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide

Advertising