2 fault detection – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 135

Advertising
background image

Digital Operator Display

Fault Name

CPF18

Control Circuit Fault
CPU error. Non-Maskable Interrupt (An unusual interrupt was triggered by noise,

etc.)

Cause

Possible Solution

Hardware is damaged.

Replace the drive.

Digital Operator Display

Fault Name

CPF19

Control Circuit Fault
CPU error (Manual reset due to noise, etc.)

Cause

Possible Solution

Hardware is damaged.

Replace the drive.

Digital Operator Display

Fault Name

or

CPF20 or

CPF21

One of the following faults occurred: RAM fault, FLASH memory error,

watchdog circuit exception, clock error
• RAM fault.
• FLASH memory error (ROM error).
• Watchdog circuit exception (self-diagnostic error).
• Clock error.

Cause

Possible Solution

Hardware is damaged.

Replace the drive.

Digital Operator Display

Fault Name

CPF22

A/D Conversion Fault
A/D conversion error.

Cause

Possible Solution

Control circuit is damaged.

• Cycle power to the drive.

Refer to Diagnosing and Resetting Faults on page

162

.

• If the problem continues, replace the drive.

Digital Operator Display

Fault Name

CPF23

PWM Feedback Fault
PWM feedback error.

Cause

Possible Solution

Hardware is damaged.

Replace the drive.

Digital Operator Display

Fault Name

CPF24

Drive Capacity Signal Fault
Entered a capacity that does not exist. (Checked when the drive is powered up.)

5.2 Fault Detection

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide

135

5

Troubleshooting

Advertising