7 main frequency reference, Dip switch s1 analog input signal selection, Dip switch s1 – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 77: Refer to, Main frequency reference

Advertising
background image

3.7

Main Frequency Reference

u

DIP Switch S1 Analog Input Signal Selection

The main frequency reference can either be a voltage or current signal input. For voltage

signals both analog inputs, A1 and A2, can be used, for current signals A2 must be used.
When using input A2 as a voltage input, set DIP switch S1 to “V” (left position) and program

parameter H3-09 to “0” (0 to +10 Vdc with lower limit) or “1” (0 to +10 Vdc without lower

limit).
To use current input at terminal A2, set the DIP switch S1 to "I" (default setting) and set

parameter H3-09 = “2” or “3” (4-20 mA or 0-20 mA). Set parameter H3-10 = “0” (frequency

reference).

Note:

If Terminals A1 and A2 are both set for frequency reference (H3-02 = 0 and H3-10 = 0), the addition of

both input values builds the frequency reference.

Table 3.12 Frequency Reference Configurations

Voltage Input

Current Input

Drive

Main speed

frequency reference

(voltage input)

Main speed

frequency reference

(current input)

Frequency reference

common

+10.5 V

20 mA current

0 to 10 V

+V

A1

A2

AC

Drive

Main speed

frequency reference

(voltage input)

Main speed

frequency reference

(current input)

Frequency reference

common

4 to 20 mA input
or
0 to 20 mA input

+10.5 V

20 mA current

+V

A1

A2

AC

3.7 Main Frequency Reference

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide

77

3

Electrical Installation

Advertising