B.1 parameter table – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 192

Advertising
background image

H1 Multi-Function Digital Input Selections

H1-

Setting

Function

Description

41

Reverse Run Command (2-wire

sequence)

Open: Stop

Closed: Reverse run

42

Run Command (2-wire

sequence 2)

Open: Stop

Closed: Run

43

FWD/REV Command (2-wire

sequence 2)

Open: Forward

Closed: Reverse

44

Offset Frequency 1 Addition

Closed: Adds d7-01 to the frequency reference.

45

Offset Frequency 2 Addition

Closed: Adds d7-02 to the frequency reference.

46

Offset Frequency 3 Addition

Closed: Adds d7-03 to the frequency reference.

47

Node Setup

Closed: Node Setup for SI-S3/V enabled.

Note: Available in drive software versions PRG: 1016 and later.

60

DC Injection Braking

Command

Closed: Triggers DC Injection Braking (b2-02)

61

External Search Command 1

Closed: Activates Current Detection Speed Search from the max. output

frequency (E1-04) if b3-01 = 0.

62

External Search Command 2

Closed: Activates Current Detection Speed Search from the frequency

reference if b3-01 = 0. Activates Speed Estimation Type Speed search if

b3-01 = 0.

65

KEB Ride-Thru 1 (N.C.)

Open: KEB Ride-Thru 1 enabled

Closed: Normal operation

66

KEB Ride-Thru 1 (N.O.)

Open: Normal operation

Closed: KEB Ride-Thru 1 enabled

67

Communications Test Mode

Tests the MEMOBUS/Modbus RS-485/422 interface.

68

High-Slip Braking

Closed: High-Slip braking is executed. Drive stops.

6A

Drive Enable

Open: Drive disabled. If this input is opened during run, then the drive will

stop as specified by parameter b1-03.

Closed: Ready for operation.

75

Up 2 Command

Open: Maintains the current frequency reference

Closed: Increases or decreases the frequency reference.

76

Down 2 Command

7A

KEB Ride-Thru 2 (N.C.)

Open: KEB Ride-Thru 2 enabled

Closed: Normal operation

7B

KEB Ride-Thru 2 (N.O.)

Open: Normal operation

Closed: KEB Ride-Thru 2 enabled

7C

Short-Circuit Braking (N.O.)

Open: Normal operation

Closed: Short-Circuit Braking

7D

Short-Circuit Braking (N.C.)

7E

Forward/Reverse Detection

Direction of rotation detection (for Simple V/f w/PG)

90 to 96 DriveWorksEZ Digital Input 1

to 7

These settings are for digital input functions used in DriveWorksEZ.

Normally there is no need to change or apply these settings.

B.1 Parameter Table

192

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide

Advertising