A.2 single/three-phase 200 v class drives, A.2 single/three-phase 200 v class, Drives – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 165

Advertising
background image

A.2

Single/Three-Phase 200 V Class Drives

Note:

Differences between Heavy Duty (HD) ratings and Normal Duty (ND) ratings for the drive include rated

input and output current, overload capacity, carrier frequency and current limit. Set parameter C6-01 to

0 for HD or 1 for ND (default).

Table A.2 Power Ratings

Item

Specification

Three-Phase Drive Model

2A0001

2A0002

2A0004

2A0006

2A0010

2A0012

2A0020

Single-Phase Drive Model

<1>

BA0001

BA0002 BA0003 BA0006 BA0010 BA0012 BA0018

Maximum Motor Size Allowed

(HP)

<3>

ND Rating

0.13

0.25

0.5/

0.75

1.0/

1.5

2.0/

3.0

3.0

5.0

<2>

HD Rating

0.13

0.25

0.5

0.75/

1.0

1.5/

2.0

3.0

5.0

Input

Input

Current
(A)

<4>

Three-

phase

ND Rating

1.1

1.9

3.9

7.3

10.8

13.9

24.0

<2>

HD Rating

0.7

1.5

2.9

5.8

7.5

11.0

18.9

Single-

phase

ND Rating

2.0

3.6

7.3

13.8

20.2

24.0

HD Rating

1.4

2.8

5.5

11.0

14.1

20.6

35.0

Output

Rated Output

Capacity (kVA)

<5>

ND Rating

0.5

0.7

1.3

2.3

3.7

4.6

7.5

<2>

HD Rating

0.3

0.6

1.1

1.9

3.0

4.2

6.7

Output Current (A)

ND Rating

<6>

1.2

1.9

3.5

(3.3)

6.0

9.6

12.0

19.6

<2>

HD Rating

0.8

<7>

1.6

<7>

3.0

<7>

5.0

<7>

8.0

<8>

11.0

<8>

17.5

<8>

Overload Tolerance

ND Rating: 120% of rated output current for 1 minute

HD Rating: 150% of rated output current for 1 minute

(Derating may be required for applications that start and stop

frequently)

Carrier Frequency

User-adjustable 2 to 15 kHz

Max Output Voltage (V)

Three-phase power: 200 to 240 V

Single-phase power: 200 to 240 V

(both proportional to input voltage)

Max Output Frequency (Hz)

400 Hz (user-adjustable)

Power

Supply

Rated Voltage

Rated Frequency

Three-phase power: 200 to 240 V 50/60 Hz

Single-phase power: 200 to 240 V 50/60 Hz

DC power supply: 270 to 340 V

<9>

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency Fluctuation

±5%

A.2 Single/Three-Phase 200 V Class Drives