No.

Name

Description

L6-01

Torque Detection Selection 1

0: Disabled

1: oL3 at Speed Agree - Alarm

2: oL3 at RUN - Alarm

3: oL3 at Speed Agree - Fault

5: UL3 at Speed Agree - Alarm

6: UL3 at RUN - Alarm

7: UL3 at Speed Agree - Fault

8: UL3 at RUN - Fault

L6-02

Torque Detection Level 1

Sets the overtorque/undertorque detection level.

L6-03

Torque Detection Time 1

Sets the length of time an overtorque/undertorque condition must exist

before Torque Detection 1 is triggered.

L6-04

Torque Detection Selection 2

Refer to V1000 Technical Manual for details.

L6-05

Torque Detection Level 2

Refer to V1000 Technical Manual for details.

L6-06

Torque Detection Time 2

Refer to V1000 Technical Manual for details.

L6-08

Mechanical Weakening (OL5)

Detection Operation

Refer to V1000 Technical Manual for details.

L6-09

Mechanical Weakening Detection

Speed Level

Refer to V1000 Technical Manual for details.

L6-10

Mechanical Weakening Detection

Time

Refer to V1000 Technical Manual for details.

L6-11

Mechanical Weakening Detection

Start Time

Refer to V1000 Technical Manual for details.

L7: Torque Limit

Use L7 parameters to configure the torque limit function.

L7-01

Forward Torque Limit

Refer to V1000 Technical Manual for details.

L7-02

Reverse Torque Limit

L7-03

Forward Regenerative Torque

Limit

L7-04

Reverse Regenerative Torque

Limit

L7-06

Torque Limit Integral Time

Constant

Refer to V1000 Technical Manual for details.

L7-07

Torque Limit Control Method

Selection during Accel/Decel

Refer to V1000 Technical Manual for details.

L8: Hardware Protection

Use L8 parameters to configure hardware protection functions.

L8-01

Internal Dynamic Braking Resistor

Protection Selection (ERF type)

0: Resistor overheat protection disabled

1: Resistor overheat protection enabled

L8-02

Overheat Alarm Level

Refer to V1000 Technical Manual for details.

L8-03

Overheat Pre-Alarm Operation

Selection

Refer to V1000 Technical Manual for details.

L8-05

Input Phase Loss Protection

Selection

0: Disabled

1: Enabled

B.1 Parameter Table

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide

201