2 fault detection – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 132

Advertising
background image

Digital Operator Display

Fault Name

A communications data error

occurred due to noise.

• Check the various options available to minimize the effects of noise.
• Counteract noise in control circuit, main circuit, and ground wiring.
• Use Yaskawa-recommended cables, or another type of shielded line. Ground

the shield on the controller side or on the drive input power side.

• Ensure that other equipment such as switches or relays do not cause noise and

use surge suppressors if required.

• Separate all wiring for communications devices from drive input power lines.

Install an EMC noise filter to the input side of the drive input power.

Digital Operator Display

Fault Name

CF

Control Fault
A torque limit was reached continuously for three seconds or longer during a ramp

to stop while in Open Loop Vector Control.

Cause

Possible Solution

Motor parameters are not set

properly.

Check the motor parameter settings and repeat Auto-Tuning.

Torque limit is too low.

Set the torque limit to the most appropriate setting (L7-01 through L7-04).

Load inertia is too big.

• Adjust the deceleration time (C1-02, -04, -06, -08).
• Set the frequency to the minimum value and interrupt the run command when

the drive finishes decelerating.

Digital Operator Display

Fault Name

CoF

Current Offset Fault
The current sensor is damaged or there was residual induction current in the motor

(e.g., during sudden deceleration or when coasting) when the drive attempted to

start the motor.

Cause

Possible Solution

Due to residual induction current in

the motor when the drive attempted

to start the motor, the drive

attempted to adjust the current

offset value beyond the allowable

range.

• Create a motor restart sequence that allows enough time for the residual

induction voltage to dissipate.

• Enable Speed Search at start (b3-01 = 1). Use the multi-function terminals to

execute External Speed Search 1 and 2 (H1- = 61 or 62).

Note: When using a PM motor, both External Speed Search 1 and 2 perform the

same operation.

Digital Operator Display

Fault Name

CPF02

A/D Conversion Error
An A/D conversion error occurred.

Cause

Possible Solution

Control circuit is damaged.

Cycle power to the drive. If the problem continues, replace the drive.

5.2 Fault Detection

132

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide

Advertising