2 fault detection – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 149

Advertising
background image

Digital Operator Display

Fault Name

PGo

PG Disconnect (for Simple V/f with PG)
No PG pulses are received for longer than the time set to F1-14.

Cause

Possible Solution

Pulse input (RP) is disconnected.

Reconnect the pulse input (RP).

Pulse input (RP) wiring is wrong.

Correct the wiring.

Motor brake engaged.

Ensure the motor brake releases properly.

Digital Operator Display

Fault Name

rH

Braking Resistor Overheat
Braking resistor protection was triggered.

Fault detection is enabled when L8-01 = 1 (disabled as a default).

Cause

Possible Solution

Deceleration time is too short and

excessive regenerative energy is

flowing back into the drive.

• Check the load, deceleration time and speed.
• Reduce the load.
• Increase the acceleration and deceleration times (C1-01 through C1-08).
• Replace the braking option with a larger device that can handle the power that

is discharged.

Excessive braking inertia.

Recalculate braking load and braking power. Then try reducing the braking load

and checking the braking resistor settings and improve braking capacity.

The proper braking resistor has not

been installed.

• Check the specifications and conditions for the braking resistor device.
• Select the optimal braking resistor.

Note: The magnitude of the braking load trips the braking resistor overheat alarm, NOT the surface temperature. Using

the braking resistor more frequently than its rating trips the alarm even when the braking resistor surface is not very

hot.

Digital Operator Display

Fault Name

rr

Dynamic Braking Transistor
The built-in dynamic braking transistor failed.

Cause

Possible Solution

The braking transistor is damaged. • Cycle power to the drive and check if the fault reoccurs.

Refer to Diagnosing

and Resetting Faults on page 162

.

• Replace the drive if the fault continues.

The control circuit is damaged.

Digital Operator Display

Fault Name

SC

IGBT Short Circuit

Cause

Possible Solution

5.2 Fault Detection

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide