Multiple drive installation – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 42

Advertising
background image

n

Multiple Drive Installation

When installing multiple drives into the same enclosure panel, mount the drives according to

Figure 2.2

. When mounting drives with a minimum side-by-side clearance of 2 mm according

to

Figure 2.3

, derating must be considered and parameter L8-35 must be set.

Refer to

Parameter List on page 175

.

2 mm

A

B

B

C

D

C

A – Line up the tops of the

drives.

B – 30 mm minimum

C – 100 mm minimum
D – Airflow direction

Figure 2.3 Space Between Drives (Side-by-Side Mounting)

Note:

When installing drives of different heights in the same enclosure panel, the tops of the drives should line

up. Leave space between the top and bottom of stacked drives for cooling fan replacement if required.

Using this method, it is possible to replace the cooling fans later.

NOTICE: When mounting IP20/NEMA Type 1 enclosure drives side by side, the top covers of all drives must

be removed as shown in

Figure 2.4

.

Figure 2.4 IP20/NEMA Type 1 Side-by-Side Mounting in Enclosure

2.1 Mechanical Installation

42

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide

Advertising