Multiple drive installation – Yaskawa J1000 Compact Vector Control Drive User Manual
Page 42

n
Multiple Drive Installation
When installing multiple drives into the same enclosure panel, mount the drives according to
. When mounting drives with a minimum side-by-side clearance of 2 mm according
, derating must be considered and parameter L8-35 must be set.
.
2 mm
A
B
B
C
D
C
A – Line up the tops of the
drives.
B – 30 mm minimum
C – 100 mm minimum
D – Airflow direction
Figure 2.3 Space Between Drives (Side-by-Side Mounting)
Note:
When installing drives of different heights in the same enclosure panel, the tops of the drives should line
up. Leave space between the top and bottom of stacked drives for cooling fan replacement if required.
Using this method, it is possible to replace the cooling fans later.
NOTICE: When mounting IP20/NEMA Type 1 enclosure drives side by side, the top covers of all drives must
Figure 2.4 IP20/NEMA Type 1 Side-by-Side Mounting in Enclosure
2.1 Mechanical Installation
42
YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide