B.1 parameter table – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 206

Advertising
background image

No.

Name

Description

U1: Operation Status Monitors

Use U1 monitors to display the operation status of the drive.

U1-01 Frequency Reference

Monitors the frequency reference.

U1-02 Output Frequency

Displays the output frequency.

U1-03 Output Current

Displays the output current.

U1-04 Control Mode

Refer to V1000 Technical Manual for details.

U1-05 Motor Speed

Displays the motor speed feedback.

Display units are determined by o1-03.

U1-06 Output Voltage Reference

Displays the output voltage.

U1-07 DC Bus Voltage

Displays the DC bus voltage.

U1-08 Output Power

Displays the output voltage (this value is determined internally).

U1-09 Torque Reference

Monitor of internal torque reference value for Open Loop Vector

(OLV) control

U1-10 Input Terminal Status

Displays the input terminal status.

U1-11 Output Terminal Status

Displays the output terminal status.

U1-12 Drive Status

Verifies the drive operation status.

U1-13 Terminal A1 Input Voltage

Displays the analog input A1 input level.

100% when the input is 10 V.

U1-14 Terminal A2 Input Voltage

Displays the analog input A2 input level.

100% when the input is 10 V / 20 mA.

U1-16 Output Frequency after Soft Start Displays the output frequency.

U1-18 OPE Fault Parameter

Displays the parameter number for oPE or Err (operator error)

where the error occurred.

U1-19 MEMOBUS/Modbus Error Code Refer to V1000 Technical Manual for details.
U1-24 Input Pulse Monitor

Displays the Pulse Train input RP frequency.

U1-25 Software No. (Flash)

Yaskawa Flash ID

U1-26 Software No. (ROM)

Yaskawa ROM ID

U1-27 Operator Message ID

Displays the numeric code of the remote operator (for use by the

manufacturer).

U1-28 Drive Message ID

Displays the numeric code of the drive (for use by the manufacturer).

U2: Fault Trace

Use U2 monitor parameters to view fault trace data.

U2-01 Current Fault

Display of the current fault.

U2-02 Previous Fault

Display of the previous fault.

U2-03 Frequency Reference at Previous

Fault

Displays the frequency reference at the previous fault.

U2-04 Output Frequency at Previous

Fault

Displays the output frequency at the previous fault.

U2-05 Output Current at Previous Fault

Displays the output current at the previous fault.

B.1 Parameter Table

206