2 fault detection – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 141

Advertising
background image

Digital Operator Display

Fault Name

Excessive torque compensation.

• Check the amount of torque compensation.
• Reduce the torque compensation gain (C4-01) until there is no speed loss and

less current.

Drive fails to operate properly due

to noise interference.

• Review the possible solutions provided for handling noise interference.
• Review the section on handling noise interference and check the control circuit

lines, main circuit lines and ground wiring.

Overexcitation gain is set too high.

• Check if fault occurs simultaneously to overexcitation function operation.
• Consider motor flux saturation and reduce the value of n3-13 (Overexcitation

Deceleration Gain).

Run command applied while motor

was coasting.

• Set b3-01 to 1 to enable Speed Search at Start.
• Program the Speed Search command input through one of the multi-function

contact input terminals (H1- = “61” or “62”).

The wrong motor code has been

entered for in OLV/PM (Yaskawa

motors only).

Enter the correct motor code to E5-01 to indicate that a PM motor is connected.

The motor control method and

motor do not match.

Check which motor control method the drive is set to in A1-02.
• For IM motors, set A1-02 to 0 or 2.
• For PM motors, set A1-02 to 5.

The motor cable is too long

Use a larger drive.

Digital Operator Display

Fault Name

oFA00

Option Card Connection Error at Option Port CN5
The option card is incompatible with the drive.

Cause

Possible Solution

The option card is incompatible

with the drive.

Use a compatible option card.

Digital Operator Display

Fault Name

oFA01

Option Card Fault
Replace the option card.

Cause

Possible Solution

The option card is not connected

properly to the drive.

Turn the power off and reconnect the option card.

Digital Operator Display

Fault Name

oFA03

Option Card Fault
Option card self-diagnostic error

oFA04

Option Card Fault
An error occurred attempting to write to the option card memory.