2 efm oam configuration, Onfiguration – PLANET WGSW-52040 User Manual

Page 122

Advertising
background image

Typical EFM OAM application topology is in the following, it is used for point-to-point link and

emulational IEEE 802.3 point-to-point link. Device enables EFM OAM through point-to-point

connection to monitor the link fault in the First Mile with Ethernet access. For user, the

connection between user to telecommunication is “the First Mile”, for service provider, it is “the

Last Mile”.

Customer

Service Provider

Customer

CE

PE

802.1ah OAMPDU

802.3ah
Ethernet in
the First Mile

Figure 14-2: Typical OAM application topology

14.2 EFM OAM Configuration

EFM OAM configuration task list

1. Enable EFM OAM function of port

2. Configure link monitor

3. Configure remote failure

Note: it needs to enable OAM first when configuring OAM parameters.

1. Enable EFM OAM function of port

Command Explanation

Port mode

ethernet-oam mode {active | passive}

Configure work mode of EFM OAM,

default is active mode.

ethernet-oam

no ethernet-oam

Enable EFM OAM of port, no

command disables EFM OAM of

port.

14-44

Advertising