background image

3. Configure remote failure

Command Explanation

Port mode

ethernet-oam remote-failure

no ethernet-oam remote-failure

Enable remote failure detection of

EFM OAM (failure means

critical-event or link-fault event of the

local), no command disables the

function. (optional)

ethernet-oam errored-symbol-period

threshold high {high-symbols | none}

no ethernet-oam errored-symbol-period

threshold high

Configure the high threshold of

errored symbol period event, no

command restores the default value.

(optional)

ethernet-oam errored-frame-period threshold

high {high-frames | none}

no ethernet-oam errored-frame-period

threshold high

Configure the high threshold of

errored frame period event, no

command restores the default value.

(optional)

ethernet-oam errored-frame threshold high

{high-frames | none}

no ethernet-oam errored-frame threshold high

Configure the high threshold of

errored frame event, no command

restores the default value. (optional)

ethernet-oam errored-frame-seconds

threshold high {high-frame-seconds | none}

no ethernet-oam errored-frame-seconds

threshold high

Configure the high threshold of

errored frame seconds event, no

command restores the default value.

(optional)