4 mrpp troubleshooting, Mrpp, Roubleshooting – PLANET WGSW-52040 User Manual

Page 448

Advertising
background image

55-19

Switch(config-If-Ethernet1/2)#exit

Switch(Config)#

55.4 MRPP Troubleshooting

The normal operation of MRPP protocol depends on normal configuration of each switch on MRPP ring,

otherwise it is very possible to form ring and broadcast storm:

Configuring MRPP ring, you’d better disconnected the ring, and wait for each switch configuration, then

open the ring.

When the MRPP ring of enabled switch is disabled on MRPP ring, it ensures the ring of the MRPP ring

has been disconnected.

When there is broadcast storm on MRPP ring, it disconnects the ring firstly, and ensures if each switch

MRPP ring configuration on the ring is correct or not; if correct, restores the ring, and then observes the

ring is normal or not.

The convergence time of MRPP ring net is relative to the response mode of up/down. If use poll mode,

the convergence time as hundreds of milliseconds in simple ring net, if use interrupt mode, the

convergence time within 50 milliseconds.

Generally, the port is configured as poll mode, interrupt mode is only applied to better performance

environment, but the security of poll mode is better than interrupt mode, port-scan-mode {interrupt | poll}

command can be consulted.

In normal configuration, it still forms ring broadcast storm or ring block, please open debug function of

primary node MRPP, and used show MRPP statistics command to observe states of primary node and

transfer node and statistics information is normal or not, and then sends results to our Technology

Service Center.