2 ddm configuration task list, Onfiguration – PLANET WGSW-52040 User Manual

Page 132

Advertising
background image

verification which are decided by the manufacturer. Besides the verification mode of the

real-time parameters and the default thresholds are same.

3. Transceiver monitoring

Besides checking the real-time working state of the transceiver, the user needs to monitor the

detailed status, such as the former abnormity time and the abnormity type. Transceiver

monitoring helps the user to find the former abnormity status through checking the log and

query the last abnormity status through executing the commands. When the user finds the

abnormity information of the fiber module, the fiber module information may be remonitored

after processing the abnormity information, here, the user is able to know the abnormity

information and renew the monitoring.

16.2 DDM Configuration Task List

DDM configuration task list:

1. Show the real-time monitoring information of the transceiver

2. Configure the alarm or warning thresholds of each parameter for the transceiver

3. Configure the state of the transceiver monitoring

1) Configure the interval of the transceiver monitoring

2) Configure the enable state of the transceiver monitoring

3) Show the information of the transceiver monitoring

4) Clear the information of the transceiver monitoring

1. Show the real-time monitoring information of the transceiver

Command Explanation

User mode, admin mode and global mode

show transceiver [interface ethernet

<interface-list>][detail]

Show the monitoring of the

transceiver.

2. Configure the alarm or warning thresholds of each parameter for the transceiver

Command Explanation

Port mode

transceiver threshold {default | {temperature |

voltage | bias | rx-power | tx-power}

{high-alarm | low-alarm | high-warn |

Set the threshold defined by the

user.

16-54

Advertising